 AC-DC
60 Watts MCM Series
* * * * * * *
xppower.com
Compact Size - High Power Density Rugged Construction Universal Input Wide Operating Temperature EMI Performance to MIL-STD-461E Convection-cooled Manufactured in the USA
Specification
Input
Input Voltage Input Frequency Inrush Current Input Protection * * * * 90-264 VAC (120-370 VDC) 47-63 Hz 40 A max at 230 VAC, cold start 25 C Internally fused
General
Efficiency Isolation * 80-85% * 4000 VAC Input to Output 1500 VAC Input to Ground 500 VAC Output to Ground * 70 kHz typical * 250 kHrs per MIL-HDBK-217F
Output
(Specification rated at Ta = 25 C & 100 % load unless specified otherwise)
Switching Frequency MTBF
Output Voltage
* 12 to 28 VDC (for other output voltages 3.3 V to 48 V please consult technical sales) Initial Set Accuracy * 1.0% Minimum Load * No minimum load required Start Up Delay * 2 s max Start Up Rise Time * 50 ms Hold Up Time * 16/75 ms minimum at 115/230 VAC Line Regulation * 0.5% Load Regulation * 1% Over/Undershoot * None at turn on/off Transient Response * 4% max. deviation, recovery to within 1% in 500 s for a 25% load change Ripple & Noise * 1% pk-pk, 20MHz BW with 1 F capacitor connected across measurement points Overvoltage Protection * 115-135% Vnom, recycle input to reset Overload Protection * 110-150%, on primary power limit, auto recovery Short Circuit Protection * Trip and restart (Hiccup mode) Temperature * 0.05% /C Coefficient
Environmental
Operating Temperature * -40 C to +70 C, derate linearly from 100% load at +50 C to 50% load at +70 C. Start up at -30 C. Cooling * Convection-cooled Operating Humidity * 95% RH, non-condensing Storage Temperature * -40 C to + 85 C Shock * 30 g pk, half sine, 6 axes Vibration * 2 g rms, 5 Hz to 500 kHz, 3 axis
EMC & Safety
Emissions EMI Immunity Safety Approvals * MIL-STD-461E, CE102, RE102 * MIL-STD 461E, CS101, 114, 115, 116 & RS103 * Designed to meet EN60950, UL60950
Mechanical
AC Input Connector DC Output Connector * AC mains lead, for UK or European mains lead contact technical sales. * D-Sub Type. For customer specfic options please contact sales.
AC-DC
Models and Ratings
Input Voltage Output Voltage 12 VDC 15 VDC 18 VDC 24 VDC 28 VDC Output Current 5.0 A 4.0 A 3.3 A 2.5 A 2.1 A Efficiency (typ) 80% 80% 81% 83% 83%
MCM
Model Number MCM60US12-D9 MCM60US15-D9 MCM60US18-D9 MCM60US24-D9 MCM60US28-D9
90-264 V
Notes
1. For extended burn-in, please contact sales.
Mechanical Details
NEMA 5-15P MOLDED CORD FEMALE DE-9 (30u/AU) MOLDED W/ 4-40 THUMBSCREWS APPROX. 0.640" 4X ROUND RUBBER FEET (0.500 X 0.150)
2.750
0.620 3.500 2X 6-32 PHIL PAN INSTALLED INTO 6-32 THREADED HOLE 5.500
1.0
0.150
1.480
5
1
9
36" +/- 6" APPROX. 48" +/- 2"
6
D-Sub Type
Notes
1. All dimensions are in inches 2. Weight: < 2.5 lbs 3. Finishing: Black epoxy paint 4. Mechanical drawing shows the `-D9' 9 Pin Output D-Sub connector. For other connectors, please contact sales. 5. For no connectors, add suffix `-NI' the part number e.g. MCM60US28-NI.
Pin 1 2 3 4 5 6 7 8 9
Output Pin Connections D-Sub Type N/C N/C N/C +Output +Output N/C N/C Return Return
Derating Curve
Output Power 100% 75% 50% 25% 0% -40 0 10 20 30 40 50 Ambient Temp (C) 60 70
18-Jul-08


▲Up To Search▲   

 
Price & Availability of MCM60US12-D9

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X